Specifications for Vertical Antenna

The Engineering Web

Breaking down requirements further we get to specifications of each major piece of this antenna system.


We continue our break down of requirements to specifications for each sub-system previously defined.

There are two sub-systems defined: Antenna Ground and Radiator. That's really no surprise for sure. These along with antenna wide requirements brings us to three groups of sub-system requirements ready to be broken down into specifications we can design and build to.

Ground and Radial Specifications

  • Antenna Ground RF resistance shall not exceed 15 ohms.
    • Minimum number of radials shall be sixty (60).
    • Minimum length of radials shall be .4 wavelength at lowest design frequency.
  • Antenna Ground shall be on or under ground level.
    • Radials shall be laid directly on the ground.
    • Radials shall be held to the ground with garden staples.
    • Central radial ground concentrator shall be set into the ground to accept radial wires at ground level.
  • Antenna Ground shall handle 1,000 watts.
    • Radial conductors shall be sized to handle 100 mA at the target RF frequencies.
    • Central ground concentrator shall be sized to handle 5 amps at the target RF frequencies.
  • Antenna Ground shall use ground level conductors.
    • Radial wires shall be insulated.
    • Radials wire insulation shall be black.

Antenna Radiator Specifications

  • Antenna Radiating Conductor shall be configurable for 10 meter band.
    • 10 meter vertical element length shall be quarter wave less end loss tuned for 28.350MHz.
  • Antenna Radiating Conductor shall be configurable for 15 meter band.
    • 15 meter vertical element length shall be quarter wave less end loss tuned for 21.300MHz.
  • Antenna Radiating Conductor shall be configurable for 20 meter band.
    • 20 meter vertical element length shall be quarter wave less end loss tuned for 14.250MHz.
  • Antenna Radiating Conductor may be configurable for 12 meter band.
    • 12 meter vertical element length may be quarter wave less end loss tuned for 24.950MHz.
  • Antenna Radiating Conductor may be configurable for 17 meter band.
    • 12 meter vertical element length may be quarter wave less end loss tuned for 18.200MHz.
  • Antenna Radiating Conductor may have multiple breakpoints.
    • Antenna vertical element shall be composed of conductive plumbing pipe with threaded connections in between.
  • Antenna Radiating Conductor shall be 1/4 wave in physical length.
    • All vertical conductors will be single quarter wave designs.
  • Antenna Radiating Conductor shall be 1/4 wave monopole at each target frequency.
    • Each band will have a unique combination of shorter conductive pieces.
  • Antenna Radiating Conductor shall handle 1,000 watts.
    • Vertical conductor shall be sized to carry 5 amps current at the base.
    • Transmission line feed conductor shall be sized to handle 5 amps.
  • Antenna Radiating Conductor shall have no capacitive and/or inductive traps.
    • Each vertical antenna conductor shall be be a full size single band antenna.
  • Antenna Radiating Conductor shall have no lumped inductances in series.
    • Vertical antenna conductor shall have no capacitive reactance requiring neutralizing with lumped inductance.
  • Antenna Radiating Conductor shall not exceed 17 feet above ground level.
    • The longest vertical antenna radiator conductor shall not exceed 17 feet in length.

Antenna Specifications

  • Antenna System corroding metal parts shall be painted or similarly protected.
    • Paint or shellac shall be applied to any metal parts that oxidize.
  • Antenna System fasteners shall have use anti-seize compound between mating surfaces.
    • Conductive anti-seize paste shall be applied to each radial attachment bolt and nut interface.
    • Conductive anti-seize paste shall be applied to u-bolt mounting hardware.
  • Antenna System feed-point shall accept Coax with PL-259 connector.
    • The central radial plate shall have a SO-238 connector.
    • The central radial plate shall directly connect the shield of the connector to the radial plate.
  • Antenna System shall be located at least 150 feet away from house.
    • Center of antenna shall be located 200 feet from house.
  • Antenna System shall use components and parts from manufacturers.
    • Radial plate shall be the DX Engineering Radial Plate.
    • SO-238 shall be the xxxx
    • The radial wire shall be household insulated wire.
    • Vertical Antenna Conductor shall be copper plumbing pipe.
    • Threaded copper fittings shall attach to sections of copper pipe.
    • Threaded copper fitting will facilitate assembly of vertical antenna into various quarter wave length.
  • Antenna System shall use Stainless Steel where possible.
    • Radial plate shall be made of Stainless Steel
    • Radial wire attaching hardware shall be made of stainless steel.
  • Antenna System should have primary angle of radiation below 45 degrees above horizon.
    • Radial wire length shall be 33 feet long.
  • Antenna System standing wave ratio (SWR) shall not exceed 2:1 at the center frequency of the vertical radiating element.
    • tbd